At Xunling Labcleantech, we understand the critical importance of maintaining a sterile and safe environment in your laboratory. Our Class II A2 Biological Safety Cabinet is designed to provide superior personnel, product, and environmental protection for your sensitive microbiological work, cell culture, and sterile pharmacy compounding needs.
Technical Specifications
Parameter/model |
BSC-1000II A2 |
BSC-1300II A2 |
BSC-1600II A2 |
Cleanliness grade |
HEPA: ISO level 5(Class 100 of 100)/ULPA: ISO level 4(class 10 of 10) |
||
Filter level/efficiency |
HEPA:≥99.995%,@0.3μm/ULPA; ≥99.999%,@0.12μm |
||
Descent wind speed |
0.33m/s |
||
Suction air speed |
0.53m/s |
||
Noise |
≤65dB |
||
Vibration half peak |
≤5μm |
||
Biosafety personnel protection |
CFU of all impact samplers≤10, CFU of slit samplers≤5 |
||
Product protection |
CFU of all sampling dishes≤5 |
||
Cross contamination protection |
CFU of all culture dishes ≤2 |
||
Workspace size |
1000*520*640mm |
1300*520*640 mm |
1600*520*640 mm |
Overall dimension of device |
1165*760*2200mm |
1465*760*2200 mm |
1765*760*2200 mm |
Specification of air supply filter |
900*470*70*① |
1290*470*70*① |
1590*470*70*① |
Specification of exhaust air filter |
650*450*90*① |
830*450*90*① |
1130*450*90*① |
Specification and quantity of fluorescent lamp/UV lamp |
30W*②/30W*① |
40W*②/40W*① |
40W*②/40W*① |
Illuminance |
≥900LX |
≥900LX |
>900LX |
Weight |
230kg |
270kg |
300kg |
Product Details
The Class II A2 Biological Safety Cabinet is engineered to provide maximum protection and comfort for the user, while ensuring the integrity of the work being conducted. Its design includes:
Ergonomic Design: The cabinet is designed to reduce operator fatigue, with adjustable features to accommodate different working styles.
Visibility: Offers excellent visibility through its large viewing window, allowing for clear observation of the work area.
Accessibility: Designed for ease of use, with simple and intuitive controls for adjusting airflow, lighting, and other parameters.
Class II A2 Biological Safety Cabinet Features
Beyond its core function of providing a safe working environment, Class II A2 Biological Safety Cabinet comes equipped with a range of features that enhance its utility and efficiency. These include:
Ultraviolet (UV) Disinfection: Optional UV lighting for additional surface decontamination.
Automatic Control: Advanced control systems for monitoring and adjusting cabinet parameters, ensuring optimal performance.
Data Recording: Capability for logging operational data, useful for quality control and compliance purposes.
Application
The versatility of the Class II A2 Biological Safety Cabinet makes it suitable for a wide range of applications across various industries, including:
Biopharmaceutical and Vaccine Manufacturers: For sterile production environments.
Medical Institutions and Clinical Laboratories: For handling pathogens and conducting microbiological tests.
Research Institutes and University Laboratories: For cell culture, virus research, and genetic engineering.
Animal Laboratories: For preventing the spread of animal pathogens.
Food Safety and Environmental Testing Institutions: For microbial detection and environmental sample analysis.
After-Sales Support
At Xunling Labcleantech, we understand the importance of ongoing support for our products. Our comprehensive after-sales service includes:
Installation and Commissioning: Expert technicians ensure your cabinet is properly installed and functioning as intended.
Operation Training: Comprehensive training for users to get the most out of their cabinet.
Regular Maintenance: Scheduled maintenance to ensure your cabinet continues to operate at peak performance.
Fault Repair: Prompt and efficient repair services in case of any issues.
Quality and Safety
Quality and safety are our top priorities. Our products are designed and manufactured to meet or exceed international standards, including NSF, EN, and CFDA certifications. We are committed to providing products that not only meet but exceed our customers' expectations for performance, reliability, and safety.
FAQ
Q: What is the difference between a Class I, Class II, and Class III Biological Safety Cabinet?
A: The main differences lie in their airflow patterns and levels of protection offered for personnel, product, and the environment.
Q: How often should the HEPA filters be replaced?
A: Replacement schedules vary based on usage, but generally, filters should be replaced every 1-2 years or as recommended by the manufacturer.
Q: Can the cabinet be customized to meet specific laboratory needs?
A: Yes, we offer customization options to fit your unique requirements, including size, features, and accessories.
Contact Us
For more information on our Class II A2 Biological Safety Cabinets, or to inquire about customization options, please do not hesitate to contact us at xalabfurniture@163.com. Our team of experts is ready to assist you in finding the perfect solution for your laboratory needs. Whether you are looking to enhance safety, improve efficiency, or expand your research capabilities, we are here to help.
YOU MAY LIKE